In-Line Check Valve

Installation Instructions

For proper function of the Valve the INDEX needs to be • installed upwards Install inline check valve as close as possible to the air • cleaner Temperature resistance of 200°C • Different connection diameters: 32 - 38 - 50 mm •

Scavenge Flow Direction

Check Valve Assy

Inlet Diameter

Outlet Diameter

P786337 P786339 P786338 P786341 P786342 P786340 P786345 P786343 P786344

32 50 38 32 50 38 32 50 38

32 32 32 38 38 38 50 50 50