FKB Air Cleaner
When specifying an Air Cleaner… Determine the Airflow Requirements of your engine, then find the corresponding m ³ /min. airflow in the charts below. The restriction numbers - shown in mbar at the left side of the chart - indicate the approximate initial restriction of each model air cleaner at that m ³ /min. When calculating total initial restriction of the entire air intake system, include the restriction caused by ducting, elbows, pre-cleaners, etc. The estimated lab life hours are indicated at the right side of the chart.
FKB Performance Curves
Performance Curves B045008
Performance Curves B055006
036 Vac Valve
Air Flow (m 3 /min)
Air Flow (m 3 /min)
3DJH
'RQDOGVRQ&RQILGHQWLDO
3DJH
'RQDOGVRQ&RQILGHQWLDO
Performance Curves B065045
Air Flow (m 3 /min)
Restr. A/c Piezo
LL62mbar
3DJH
'RQDOGVRQ&RQILGHQWLDO
Restr. A/c Piezo
LL62mbar
3DJH All performance curves are according ISO 5011 standards - Restriction measured at Piezo All tests are done with ISO Coarse at Dust Concentration of 1g/m³
Engine Air Cleaners, Accessories & Service Parts n 53
Powered by FlippingBook