Donaldson Engine Air Filter Catalogue

FLB Air Cleaner

Two-Stage Louvered Body Air Cleaner

The FLB - Louvered Body Air Cleaner is a two-stage air cleaner with scavenge exhaust system and Axial Seal Sealing Technology. Body diameters in 6", 8", 10" and 12". Handles airflows of 3-17 m³/min. Sustained temperature tolerance: to 82°C. Designed especially for combines and other heavy-duty construc- tion and agricultural equipment operating in severe dust, fibers, lint and shaft environments. To be used with an exhaust ejector. For all available Donaldson Exhaust Ejectors, see page 124-125.

FLB Specifications - Service Parts

Air Cleaner Model No

Airflow Range

Dimensions (mm)

m³/min.

A

B

D

F

G

B065018 B080022 B100067 B120260

3 - 5

167 203 259 300

360 423 430 424

76 89

28 54 50 80

32 32 32 32

345 415 425 415

4,5 - 7

7 - 12

101 127

12 - 17

X° Free space needed to remove main element

Service Parts

Air Cleaner Model No.

Main

Safety

Mounting

Filter

Element

Element

Band*

Wing Nut

B065018 B080022 B100067 B120260

P772565 P772556 P772530 P772520

P770207 P119410 P133138 P770678

P007191 P004307 P004076 H000349

P138403 P138403 P138403 P134803

* Two mounting bands needed per Air Cleaner

90 n Engine Air Cleaners, Accessories & Service Parts