FLB Air Cleaner
Two-Stage Louvered Body Air Cleaner
The FLB - Louvered Body Air Cleaner is a two-stage air cleaner with scavenge exhaust system and Axial Seal Sealing Technology. Body diameters in 6", 8", 10" and 12". Handles airflows of 3-17 m³/min. Sustained temperature tolerance: to 82°C. Designed especially for combines and other heavy-duty construc- tion and agricultural equipment operating in severe dust, fibers, lint and shaft environments. To be used with an exhaust ejector. For all available Donaldson Exhaust Ejectors, see page 124-125.
FLB Specifications - Service Parts
Air Cleaner Model No
Airflow Range
Dimensions (mm)
m³/min.
A
B
D
F
G
X°
B065018 B080022 B100067 B120260
3 - 5
167 203 259 300
360 423 430 424
76 89
28 54 50 80
32 32 32 32
345 415 425 415
4,5 - 7
7 - 12
101 127
12 - 17
X° Free space needed to remove main element
Service Parts
Air Cleaner Model No.
Main
Safety
Mounting
Filter
Element
Element
Band*
Wing Nut
B065018 B080022 B100067 B120260
P772565 P772556 P772530 P772520
P770207 P119410 P133138 P770678
P007191 P004307 P004076 H000349
P138403 P138403 P138403 P134803
* Two mounting bands needed per Air Cleaner
90 n Engine Air Cleaners, Accessories & Service Parts