EPB – ERB2 Air Cleaner with Donaspin™ Pre-Cleaner
When specifying an Air Cleaner… Determine the Airflow Requirements of your engine, then find the corresponding m ³ /min. airflow in the charts be- low. The restriction numbers - shown in mbar - indicate the approximate initial restriction of each model air cleaner at that m ³ /min. If there are two air cleaner models that fit your paramaters, choosing the one with the lowest re- striction will provide the longest service life. When calculating total initial restriction of the entire air intake system, include the restriction caused by ducting, elbows, pre-cleaners, etc.
Restriction Curves
Performance Curves B070005 + PLH001212
Performance Curves B080067 + PLH001307
12 16 20 24 28 32 36 40
54
48
42
36
30
24
18
12
0 4 8
6
0
3
4
5
6
7
2
3
4
5
6
Air Flow (m³/min)
Air Flow (m³/min)
Restr. A/c Piezo
'RQDOGVRQ&RQILGHQWLDO 3DJH
'RQDOGVRQ&RQILGHQWLDO
Performance Curves B100126 + PLH001215
36
32
28
24
20
16
12
8
4
0
3
4,5
6
7,5
9
Air Flow (m³/min)
3DJH
'RQDOGVRQ&RQILGHQWLDO
Restr. A/c Piezo
All performance curves are according ISO 5011 standards - Restriction measured at Piezo All tests are done with ISO Coarse at Dust Concentration of 1g/m³
94 n Engine Air Cleaners, Accessories & Service Parts
Powered by FlippingBook