Engine Liquid Filtration Product Guide

Fuel Filtration 93 mm / 3.66" Filter Diameter

Filter Selection Chart

Maximum Recommended Flow Rate

Efficiency @ 99% per ISO 19438

Filter Length*

Part Number

99% EFFICIENCY

Filter Style

Media Type

lph gph mm in

Primary Standard Drain

P581681 † P581682 † P553203

4 μm

227

60 155.2 6.11

Cellulose

10 μm

Cellulose

4 μm

265

70 194.1 7.64

Synteq Synthetic

P550847

10 μm

P553207

Cellulose

4 μm

Synteq Synthetic

P553201

340

90 219.3 8.63

10 μm

P553204

Cellulose

35 μm

Synteq Synthetic

P551000

400 105 252.0 9.92

10 μm

Secondary No Drain

P557440 ‡ P553854 ‡ P555627 ‡

Cellulose

9 μm

303

80

174 6.85

Cellulose

25 μm

379 100 200 7.87

Cellulose

9 μm

* Water Collection Bowl (part no. P569758 ) adds 50 mm / 1.98 in. to filter length. † Lead times may apply. Please contact your Donaldson sales representative for lead time details. ‡ For use on non-high pressure common rail fuel systems only. For Tier 4 applications, contact your Donaldson sales representative.

Maximum Recommended Flow Rate

Efficiency @ 99.9% per ISO 19438

Filter Length

99.9% EFFICIENCY

Part Number

Filter Style

Media Type

lph gph mm in

Secondary

P551313

Cellulose

5 μm

340

90 174.0 6.85

Synteq XP Synthetic

DBF5814

4 μm

P551311

Cellulose

5 μm

450 120 232.8 9.17

Synteq XP Synthetic

DBF5817

4 μm

20 • Engine Liquid Filtration

shop.donaldson.com