FPK 02 & 04 – AP220
Indicator Choices
Setting (bar)
Protection Class
Part
Kind
Reference Drawing
Contact
Cable Clamp
Max. Values
P763975 Electrical
Differential
B
2,75
Normally Open
6-30V DC; 0,2 A
P763976 Electrical
Differential
B
2,75
Normally Closed
6-30V DC; 0,2 A
P761058
Visual
Differential
H
3
P761057 Electrical
Differential
L
3
Normally Open/Closed
IP65
PG11
30 V DC; 0,5 A res. and 0,2 A ind.
P171087 Electrical
Differential
M
2,75
Normally Open
Packard Connector
6-30 V DC; 200 mA
Installation & Service Guidelines
Optional Head
Standard Head
AP 221-222
P173392 P173390
Reference Drawing B, H, L or M
Important • The bowl thread must be lubricated before spinning on the head to prevent thread damage. Heavyweight gear lube is recommended. • Oil the O-Rings before assembly.
Bowl
Optional Head
Standard Head
AP 223-224-225
Reference Drawing B, L, H or M
P761095 P761094
Bowl