Donaldson Hydraulic Filters Catalog

FIK-FIS

Components

WIRE MESH

CELLULOSE MEDIA

SYNTHETIC MEDIA

/9

/6

/3

/1

/03

XP10

CARTRIDGE CODE

90 “ m

60 “ m

50 “ m(c) • 1000

ß 36 “ m(c) • 1000

ß 23 “ m(c) • 1000

ß 11 “ m(c) • 1000

ß

Family

RMF

RMF

RMF

RMF

RMF

RMF

FIS20

20

P171829

20

P171832

15

P171835

15

P171838

10

P171841

10

P171844

CR20 CR40 CR50 CR60

FIS40

40

P171830

40

P171833

30

P171836

30

P171839

25

P171842

25

P171845

FIS50

40

P171830

40

P171833

30

P171836

30

P171839

25

P171842

25

P171845

FIS60

60

P171524

60

P171529

40

P171528

40

P171527

35

P171526

35

P171525

FIS100

100

P171530

100

P171535

65

P171534

65

P171533

60

P171532

60

P171531

CR100 CR150 CR200

FIS150

150

P171831

150

P171834

120

P171837

120

P171840

110

P171843

110

P171846

FIS200

200

P766606

200

P766607

150

P766608

150

P766609

130

P766610

130

P766611

RMF = Recommended Maximum Flow in liters/minute with use of standard housing. S= Service Clearance Maintain the filter outlet (ref. diameter G) well below the oil level to avoid foam formation.

Breather Choices

NO MEDIA

CELLULOSE MEDIA

With pressurization relief setpoint at 0.4 bar

Without pressurization

REMARK

closes of breather hole

10 “ m

10 “ m

Family

RMF

RMF

not available Breather with T.R.A.P. ™ Technology

FIS20, 40, 50

P766927 (plug)

150 150

P567392 (black)

150 150

FIS60, 100, 150, 200

P766528 (black)

P766530 (blue)

P766538 (red)

Breather with T.R.A.P. ™ Technology

The head is open, to avoid contamination entering the tank, you have to install a breather.

Dipstick Choices

For Family

DIPSTICK

IN TANK LENGTH

USE HOLE DIAMETER

FIS20

P766623 P766624 P766552 P766621

138 293 150 305

M10 M10

FIS40, 50 FIS60, 100 FIS150, 200

E or F E or F

52 • Hydraulic Filters & Accessories

Powered by